7
7
7
7
10
10
16
16
14
14
25
25
51
51
54
54
53
53
17
17
2020
2009
University (324)Hospital (26)Research Institution (17)Company (7)
1 - 10 of 324
Sort by
Publication
ID32122152Published Date2020-03-03JournalAmerican journal of health promotion : AJHP, 2020-03-03
To describe the development of the first disease prevention intervention with ultra-Orthodox Jewish (UOJ) women in Israel using mixed methods and community-based participatory research (CBPR).This collaborative, 7-staged development process used an exploratory sequential mixed methods design integrated into a community-based participatory approach.The UOJ community in Israel, a high-risk, low socioeconomic, culturally insular minority that practices strict adherence to religious standards, ma…
Publication
ID32069760Published Date2020-03-01JournalEnvironmental research, 2020-03-01, Volume 182
Human biomonitoring (HBM) data is increasingly being compared to risk-based screening values to assess human health risk. However, as screening values have not been established for assessing biomarker concentrations of organophosphate (OP) pesticide metabolites, there are few studies using HBM data on urinary OP concentrations to assess human health risk. The purpose of the current study was to measure OP exposure in a sample of children in Israel; to explore associations between dietary patt…
Publication
ID32078607Published Date2020-03-01JournalOncology nursing forum, 2020-03-01, Volume 47
To describe and compare self-perceived end-of-life (EOL) knowledge, attitudes, behaviors, and practices of intensive care unit (ICU) nurses compared to oncology nurses.126 Israeli nurses (79 oncology nurses and 47 ICU nurses) who were members of the Israel Association of Cardiology and Critical Care Nurses and the Israeli Oncology Nurses Organization.This cross-sectional study used an online survey to gather demographic information, clinical setting, and study measures (EOL knowledge, attitud…
Publication
ID31982340Published Date2020-03-01JournalVeterinary anaesthesia and analgesia, 2020-03-01, Volume 47
Factors described as contributors to the 'penumbra effect' in relation to pulse oximetry include optical shunting, circulatory anastomoses and probe parallelity. This study aimed to clarify the main underlying mechanism involved.Prospective clinical trial.A total of 30 dogs and 15 cats (client-owned).In anaesthetized dogs and cats, a pulse oximeter probe was placed on the tongue to measure haemoglobin oxygen saturation (SpO) and perfusion index. In 15 dogs, the probe was positioned at the roo…
Publication
ID32109903Published Date2020-02-28JournalPhysiological measurement, 2020-02-28
Objective The commonly used noninvasive techniques for blood pressure measurement, auscultatory Korotkoff-based sphygmomanometry and oscillometry, both have limitations in their clinical use. The former is relatively accurate but is limited to use in a physician's office because its automatic variant is subject to noise artifacts. Automatic oscillometers can be used at home, but their accuracy is low. In the current study, we present two electronic techniques for systolic blood pressure (SBP)…
Patent
Publication NumberUS 20200036155Filing StatusPatent ApplicationAvailabilityUnknownFiling Date2018-04-02Publication Date2020-01-30
A laser system, comprised of: a laser cavity; a gain medium a pump, a saturable absorber (SA); a first mirror and a second mirror; wherein a ratio of an area of the laser beam within the gain medium to an area of the beam area within the SA is greater than 1, and wherein the beam generates a gain medium radius spot on the gain medium and a saturable absorber radius spot on the saturable absorber such that a ratio between the gain medium radius spot on the gain medium and a saturable absorber …
Patent
Publication NumberUS 20200020683Filing StatusPatent ApplicationAvailabilityUnknownFiling Date2018-03-06Publication Date2020-01-16
A novel electric rectifier for use in a rectenna device is provided. The rectenna device can advantageously be used in a variety of applications. The electric rectifier comprises an integrated structure comprising: a diode structure comprising first and second electrodes located in first and second conductive layers respectively and an insulating layer between them, the diode structure being configured and operable for receiving an input signal and generating output signal indicative thereof,…
Patent
Publication NumberEP 3593385 A1Filing StatusPatent ApplicationAvailabilityUnknownFiling Date2018-03-06Publication Date2020-01-15
Publication
ID31403529Published Date2020-01-01JournalCornea, 2020-01-01, Volume 39
To describe a new method to distinguish between normal versus lipid-deficient dry eye using a Tear Film Imager (TFI).Two groups of study subjects, controls versus lipid-deficient dry eye, were tested using the TFI. This instrument provides an accurate measurement of the thickness and spatial distribution of the muco-aqueous and lipid layers of the tear film. The nanometer thickness resolution of the TFI enables the creation of detailed maps of the lipid layer thickness (LLT) across the cornea…
Publication
IDDOI:10.4018/978-1-7998-2355-1.ch009Published Date2020-01-01JournalKnowledge Management, Innovation, and Entrepreneurship in a Changing World, 2020-01-01
This chapter examines the relationship between task-communication and five collaborative processes by exploring the mediating effect of interpersonal trust in a virtual team's environment. First, a multiple mediation model was developed to examine this relationship where cognitive-based trust and affective-based trust are defined as mediation variables between task-communication and five processes of collaboration. Then, employing qualitative thematic analysis, authors constructed a conceptua…
We found 324 documents that match your Search
Research Grants: 1
Publications: 307
Patents: 16

Wellspring Search is the world's most comprehensive collection of enriched content about emerging and licensable technology innovations.


Already a member? Sign in